Model SPF-290AS: The SPF-290AS Sunscreen Protection Factor Analyzer is delivered as an integrated turnkey system packaged in a self-contained, attractive desktop unit. The SPF-290AS Computer includes a CPU, keyboard, monitor, mouse, Windows® operating system, data acquisition board, drivers, I/O, communication and power cables, WinSPF operating software, and complete instruction manual.
WinSPF operating software is installed and tested, and includes complete on-line help system, audio- visual training aid, COLIPA spreadsheet, fully functional toolbar, single step control icons, graphical and tabular data display formats.

To begin immediate testing at system delivery, a 50 x 50 mm PMMA plate holder, along with a sample set of three 5μ roughness PMMA plates and a box of 25 syringes for sample application are also provided. P2 and S2 standard sunscreens are also supplied for testing ISO 24443, FDA, and much more.

The SPF-290AS is the choice for hundreds of the world’s leading companies including Avon, BASF, Clairol, Elizabeth Arden, Estee Lauder, Good Housekeeping, ISP, Johnson & Johnson, Lever Bros, L’Oreal, Mary Kay, Merck, Revlon, Rohm & Haas, Proctor & Gamble, Unilever, Andrew Jergens, Helene Curtis, Whitehall Robins, Bayer, S.C. Johnson, Bristol-Myers Squibb, Tanning Research, Pfizer, Boots the Chemist, UK Ltd., Amway and many others!

Specifications

SPF-290AS Performance Specifications

 Wavelength Range290 – 400 nm (Range Specified by International Standards)
Wavelength Accuracy0.2% (0.58 nm – 0.80 nm)
Wavelength Reproducibility0.25 nm
Spectral Bandwidth (FWHM)1.66 nm
Wavelength Step Interval1 nm, 2 nm, or 5 nm (User Selectable)
Absorbance Range0 – 3.2 A (Dual Doped PMMA Method)
SPF Measurement Range1 – 100+
UPF Measurement Range1 – 100+
Scan TimeAs Little As 24 Seconds
Wavelength Step Interval1 nm, 2 nm, or 5 nm (User Selectable)
LampNewly designed Power Stabilized Xenon 175W
DetectorHigh Sensitivity Multialkali side-on PMT
Sample PositioningAutomated X-Y Stage (12 discrete sample positions)
Power Options110V AC, 60 Hz or 220V AC, 50 Hz