Sunscreen Analyzer SPF-290AS
SPF-290AS Sunscreen Protection Factor Analyzer to meet the latest ISO24443 requirements. Works on 120 VAC, 60 Hz, single-phase AC power. (220 VAC, 50 Hz, single-phase version available optionally at no extra cost – please specify at order). Kit includes:
• All-in-one Touch screen Computer
• Software
• Validation Kit
• Packing & Handling
Description
Model SPF-290AS: The SPF-290AS Sunscreen Protection Factor Analyzer is delivered as an integrated turnkey system packaged in a self-contained, attractive desktop unit. The SPF-290AS Computer includes a CPU, keyboard, monitor, mouse, Windows® operating system, data acquisition board, drivers, I/O, communication and power cables, WinSPF operating software, and complete instruction manual.
WinSPF operating software is installed and tested, and includes complete on-line help system, audio- visual training aid, COLIPA spreadsheet, fully functional toolbar, single step control icons, graphical and tabular data display formats.
To begin immediate testing at system delivery, a 50 x 50 mm PMMA plate holder, along with a sample set of three 5μ roughness PMMA plates and a box of 25 syringes for sample application are also provided. P2 and S2 standard sunscreens are also supplied for testing ISO 24443, FDA, and much more.
The SPF-290AS is the choice for hundreds of the world’s leading companies including Avon, BASF, Clairol, Elizabeth Arden, Estee Lauder, Good Housekeeping, ISP, Johnson & Johnson, Lever Bros, L’Oreal, Mary Kay, Merck, Revlon, Rohm & Haas, Proctor & Gamble, Unilever, Andrew Jergens, Helene Curtis, Whitehall Robins, Bayer, S.C. Johnson, Bristol-Myers Squibb, Tanning Research, Pfizer, Boots the Chemist, UK Ltd., Amway and many others!
Specifications
SPF-290AS Performance Specifications
Wavelength Range | 290 – 400 nm (Range Specified by International Standards) |
Wavelength Accuracy | 0.2% (0.58 nm – 0.80 nm) |
Wavelength Reproducibility | 0.25 nm |
Spectral Bandwidth (FWHM) | 1.66 nm |
Wavelength Step Interval | 1 nm, 2 nm, or 5 nm (User Selectable) |
Absorbance Range | 0 – 3.2 A (Dual Doped PMMA Method) |
SPF Measurement Range | 1 – 100+ |
UPF Measurement Range | 1 – 100+ |
Scan Time | As Little As 24 Seconds |
Wavelength Step Interval | 1 nm, 2 nm, or 5 nm (User Selectable) |
Lamp | Newly designed Power Stabilized Xenon 175W |
Detector | High Sensitivity Multialkali side-on PMT |
Sample Positioning | Automated X-Y Stage (12 discrete sample positions) |
Power Options | 110V AC, 60 Hz or 220V AC, 50 Hz |